COMMERCIAL BIOSHIELD ® CLP

Establishing a bio-secure swimming facility begins at the pool design stage. Low-pressure UV systems are a proven solution to harmful waterborne pathogen problems and irritating chloramines. Pentair BioShield Commercial UV systems provide instant protection against Cryptosporidium, Giardia and remove chloramines.

Featured Highlights

Energy efficient Low Pressure UV converts up to 30-40% energy into UV-C light
Cost effective UV inhibited Schedule 80 PVC vessels stand up to UV degradation and corrosion caused by pool water
Conserve free-chlorine by as much as 30% compared to Medium Pressure UV systems
NSF certified with flow rates up to 2,335 GPM
Quality American-made, low-pressure Amalgam UV lamps offer up to 12,000 hours of continuous operation
Low temperature lamps conserve energy and negate the need for quartz sleeve wiper systems
UL 508L Listed
Single-end UV lamp and quartz sleeve access for easy servicing
Choice of input / output piping connections
Enhanced, state of the art electronic ballast, sized precisely to the lamp's power requirement, ensures optimal UV-C output and maximum useful lamp life
Most effective and efficient UV-spectral power distribution

Microprocessor Standard Feature

Touch Screen Interface
Power Enclosure Over-Temp. Safety Shut-Down
Vessel Over-Temp. safety Shut-Down
Individual Lamp Status and Re-settable Hour Meter
Master System Hour Meter
Output Alarm Relay
UV Intensity Monitor (1% - 100% Scale)
Thermoplastic NEMA 12 Enclosure
External Power Switch
20 Foot Lamp Cables
Enclosure Cooling Fan
Modbus Communication

Sizing Your Bioshield UV System

1 Establishing flow rate requirements in GPM is critical to selecting the correct UV system for your application.
2 Know your UVT and dose requirement. UVT is the measure of UV-C light transmittance (254nm) in water. Contaminates and waterborne agents Suspended in water will absorb UV light, preventing transmittance. Pentair has selected 90% UVT as a realistic measure of light transmittance in swimming pool water. Other manufacturers may use a higher UVT% which can greatly overrate flow capacity. Dose is a factor of UV light intensity and contact time. Pentair calculates two average dose levels for pool applications as follows: UV Dose Commercial Application 40 mJ/cm² Inactivation of Cryptosporidium and other chlorine tolerant pathogens 60 mJ/cm ² Additional breakdown of chloramines for greatly improved air and water quality.
3 Choose your BioShield UV system model. Select desired dose column below. Identify maximum flow rate that meets system flow rate requirement. Complete this step for model CLP4 or CLP6 and with provided vessel and power enclosure dimensions, choose the best model suited for the mechanical space. *Note max flow rate for desired port size on each model.

Ordering Information

Model² Lamps/Watts UV-C Spectrum Output Watts Max. Flow Rate at 90% UVT 40 mJ/cm²(GPM) Max. Flow Rate at 90% UVT 60 mJ/cm²(GPM) Port Size Max. Flow for Port Size Amps Max Load@ 120/230 VAC UV Vessel Dimension³(AxBxC) Power Enclosure Dimensions (HxWxD) Max PSI
CLP4
CLP41A6-XN 1/130 40 49 33 2” - 2.1/1.0 56”xØ6”x47” 16”x14”x8.4” 100
CLP42A6-XN 2/130 80 90 60 2” *64 3.9/2.0 56”xØ6”x47” 16”x14”x8.4” 100
CLP42A6-XN 2/130 80 90 60 3” - 3.9/2.0 56”xØ6”x47” 16”x14”x8.4” 100
CLP43A6-XN 3/130 120 125 83 3” - 5.8/2.9 56”xØ6”x47” 16”x14”x8.4” 100
CLP43A8-XN 3/130 120 167 111 3” *144 5.8/2.9 62”xØ8”x51” 16”x14”x8.4” 100
CLP43A8-XN 3/130 120 167 111 4” - 5.8/2.9 62”xØ8”x51” 16”x14”x8.4” 100
CLP44A8-XN 4/130 160 227 151 3” *144 7.5/3.7 62”xØ8”x51” 20.2”x16.3”x8.4” 100
CLP44A8-XN 4/130 160 227 151 4” - 7.5/3.7 62”xØ8”x51” 20.2”x16.3”x8.4” 100
CLP45A8-XN 5/130 200 272 181 4” *251 9.4/4.7 62”xØ8”x51” 24.6”x20.2”x10.6” 100
CLP45A8-XN 5/130 200 272 181 6” - 9.4/4.7 62”xØ8”x51” 24.6”x20.2”x10.6” 100
CLP46A10-XN 6/130 240 365 244 4” *251 11.2/5.6 64”xØ10”x51” 24.6”x20.2”x10.6” 100
CLP46A10-XN 6/130 240 365 244 6” - 11.2/5.6 64”xØ10”x51” 24.6”x20.2”x10.6” 100
CLP47A10-XN 7/130 280 430 287 6” - 13.3/6.5 64”xØ10”x51” 24.6”x20.2”x10.6” 100
CLP47A12-XN 7/130 280 492 328 6” - 13.3/6.5 69”xØ12”x51” 24.6”x20.2”x10.6” 75
CLP48A12-XN 8/130 320 555 369 6” - 15.0/7.5 69”xØ12”x51” 30.5”x24.1”x12.6” 75
CLP6 (Only Available in 230VAC)
CLP61A6-XN 1/320 98 113 75 2” *64 3.2/1.6 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP61A6-XN 1/320 98 113 75 3” - 3.2/1.6 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP62A6-XN 2/320 196 200 133 3” *144 6.0/3.0 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP62A6-XN 2/320 196 200 133 4” - 6.0/3.0 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP63A6-XN 3/320 294 279 186 4” *251 9.0/4.5 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP63A6-XN 3/320 294 279 186 4” - 9.0/4.5 85”xØ6”x76” 24.6”x20.2”x10.6” 100
CLP63A8-XN 3/320 294 372 247 4” *251 9.0/4.5 86”xØ8”x76” 24.6”x20.2”x10.6” 100
CLP63A8-XN 3/320 294 372 247 6” - 9.0/4.5 86”xØ8”x76” 24.6”x20.2”x10.6” 100
CLP64A8-XN 4/320 392 505 336 6” - 12.0/6.0 86”xØ8”x76” 24.6”x20.2”x10.6” 100
CLP65A8-XN 5/320 490 606 403 6” *569 15.0/7.5 86”xØ8”x76” 24.6”x20.2”x10.6” 100
CLP65A8-XN 5/320 490 606 403 6” - 15.0/7.5 86”xØ8”x76” 24.6”x20.2”x10.6” 100
CLP66A10-XN 6/320 588 814 542 6” *569 18.0/9.0 88”xØ10”x76” 30.5”x24.1”x12.6” 100
CLP66A10-XN 6/320 588 814 542 8” - 18.0/9.0 88”xØ10”x76” 30.5”x24.1”x12.6” 100
CLP67A10-XN 7/320 686 953 638 6” *569 11.0¹ 88”xØ10”x76” 30.5”x24.1”x12.6” 100
CLP67A10-XN 7/320 686 953 638 8” - 11.0¹ 88”xØ10”x76” 30.5”x24.1”x12.6” 100
CLP67A12-XN 7/320 686 1095 729 8” *996 11.0¹ 90”xØ12”x76” 30.5”x24.1”x12.6” 75
CLP67A12-XN 7/320 686 1095 729 10” - 11.0¹ 90”xØ12”x76” 30.5”x24.1”x12.6” 75
CLP68A12-XN 8/320 784 1235 823 8” *996 13.0¹ 90”xØ12”x76” 30.5”x24.1”x12.6” 75
CLP68A12-XN 8/320 784 1235 823 10” - 13.0¹ 90”xØ12”x76” 30.5”x24.1”x12.6” 75
CLP69A14-XN 9/320 882 1462 974 8” *996 14.0¹ 92”xØ14”x76” 30.5”x24.1”x12.6” 50
CLP69A14-XN 9/320 882 1462 974 10” - 14.0¹ 92”xØ14”x76” 30.5”x24.1”x12.6” 50
CLP610A16-XN 10/320 980 1690 1127 10” *1567 16.0¹ 94”xØ16”x76” 30.5”x24.1”x12.6” 50
CLP610A16-XN 10/320 980 1690 1127 12” - 16.0¹ 94”xØ16”x76” 30.5”x24.1”x12.6” 50
CLP611A18-XN 11/320 1078 1963 1308 10” *1567 17.0¹ 96”xØ18”x76” 40.4”x32.5”x12.6” 50
CLP611A18-XN 11/320 1078 1963 1308 12” - 17.0¹ 96”xØ18”x76” 40.4”x32.5”x12.6” 50
CLP612A20-XN 12/320 1176 2335 1555 10” *1567 19.0¹ 98”xØ20”x76” 40.4”x32.5”x12.6” 50
CLP612A20-XN 12/320 1176 2335 1555 12” *2218 19.0¹ 98”xØ20”x76” 40.4”x32.5”x12.6” 50
CLP612A20-XN 12/320 1176 2335 1555 14” - 19.0¹ 98”xØ20”x76” 40.4”x32.5”x12.6” 50

Note

¹ 230VAC Only. When ordering optional 230VAC add “-2” to end of part number.
² When ordering: Replace 'X' in part number with requested flange size; eg. '2' for two-inch flange.
³ Vessel dimension "C" represents clearance requirement for glassware maintenance.
! CALIFORNIA PROPOSITION 65 WARNING WARNING: Cancer and Reproductive Harm. AVERTISSEMENT: Peut Causer le Cancer et des Dommages au Système Reproducteur. ADVERTENCIA: Cáncer y Daño Reproductivo. P/N 200174.A www.p65warnings.ca.gov.

Contact Us

Your message has been sent. Thank you!
Valid mobile number Invalid mobile number