COMMERCIAL ACU DRIVE™ XS

The Acu Drive XS VF Drive offers built-in intelligence for increased performance in all aquatic pump applications. Specified to save money, energy and time, the Acu Drive XS VF Drive offers very fast return on investment. The Acu Drive XS VF Drive allows the pump to run at its most efficient point on the curve. Preventative maintenance costs will drop due to motor protection, motor soft start, and a significant decrease in water hammer protecting the shaft and impeller. Up to an additional 5% savings due to the Acu Drive XS VF Drive’s ability to balance power phase and harmonic suppression. Built with powerful standard and optional features specifically designed for energy optimization, the Acu Drive XS VF Drive is perfectly matched with the full line of Pentair Commercial pumps.

Featured Highlights

Save up to 60% or more on pump’s electricity usage
“Right-size” your pump to the exact flow required
Saves energy with constant flow as the filters gets dirty (with optional flow sensor)
Off-hour flow management capability
Does not blow corrosive filter-room air across the circuitry
High efficiency up to 98% – adjusts drive input voltage for best efficiency point
Eliminates need for motor starters
Integrated disconnects, fusing and optional bypasses
2-step ramps (Soft Start Feature)
Real-time clock for time based functions
Great match for 3-phase models of EQ Series® Pumps
Overload trip protection protects motor and Acu Drive XS VF Drive from Voltage Spikes and phase unbalance
Can connect to an IntelliTouch® Automation System
Up to a six year on-site warranty available
Start-up included with every drive (technical training option available)
Indoor & Outdoor-rated enclosures
One drive type for the full power range
For use with 3 phase pumps only
Acu Drive XS VF Drives with single phase input power available

Ordering Information

Horse Power (HP) 200–240 VAC NEMA RATED 1 (IP 20/21) 360–480 VAC 525–600 VAC 200–240 VAC NEMA RATED 12 (IP 54/55) 360–480 VAC 525–600 VAC
3 PHASE INCLUDES FUSED DISCONNECT, ON-SITE START-UP* AND BATTERY BACK-UP
3 AD030-2303-N01 AD030-4603-N01 AD030-5753-N01 AD030-2303-N12 AD030-4603-N12 AD030-5753-N12
5 AD050-2303-N01 AD050-4603-N01 AD050-5753-N01 AD050-2303-N12 AD050-4603-N12 AD050-5753-N12
7-1/2 AD075-2303-N01 AD075-4603-N01 AD075-5753-N01 AD075-2303-N12 AD075-4603-N12 AD075-5753-N12
10 AD100-2303-N01 AD100-4603-N01 AD100-5753-N01 AD100-2303-N12 AD100-4603-N12 AD100-5753-N12
15 AD150-2303-N01 AD150-4603-N01 AD150-5753-N01 AD150-2303-N12 AD150-4603-N12 AD150-5753-N12
20 AD200-2303-N01 AD200-4603-N01 AD200-5753-N01 AD200-2303-N12 AD200-4603-N12 AD200-5753-N12
SINGLE PHASE INPUT DRIVES (FOR USE WITH 3 PHASE PUMPS ONLY) INCLUDES DISCONNECT ONLY (NO FUSES) ON-SITE START-UP* AND BATTERY BACK-UP
3 AD030-2301-N01 AD030-2301-N12
5 AD050-2301-N01 AD050-2301-N12
7-1/2 AD075-2301-N01 AD075-2301-N12
10 AD100-2301-N01 AD100-2301-N12
15–20 AD200-2301-N01 AD200-2301-N12
For 25 HP and higher and Nema 4 options - Please contact factory.

Optional A & W

208–230 Volts 380–690 Volts
DURATION 3 HP & Below 5–25 HP 10 HP & Below 15–40 HP
3 YEAR AD-EWW136 AD-EWW236 AD-EWW136 AD-EWW236
6 YEAR AD-EWW172 AD-EWW272 AD-EWW172 AD-EWW272
Note – A & W (Accessories and Warranties)

Product and Description

ACU DRIVE VF DRIVE FLOW SENSOR KITS WITH INTEGRAL 4-20 OUTPUT SIGNAL, INCLUDES PVC CLAMP-ON SADDLE FOR DISPLAY ON ACU-DRIVE ONLY (DOES NOT INCLUDE SEPARATE WALL-MOUNT DISPLAY)
Product Description
97014-4203KIT 3 in. Flow sensor kit with 4-20 output
97014-4204KIT 4 in. Flow sensor kit with 4-20 output
97016-4206KIT 6 in. Flow sensor kit with 4-20 output
97016-4208KIT 8 in. Flow sensor kit with 4-20 output

Note

* Additional charges will apply if on-site start-up exceeds four hours (including round-trip travel) per Acu Drive VF Drive.
Other options and add-ons are available including Nema Rated 4X (IP66) enclosure, “Fused Bypass” upgrade, and additional on-site technical training. For more information on these options, other sizes, or applications assistance call 1-800-831-7133.
Some pump motors (e.g. 230/460V versions) can be wired to accommodate multiple voltages. This is not true of VFDs. In order to ensure proper VFD selection, the actual pump motor input voltage must be consistent with the drives operating range as shown.
The Acu Drive VF Drive is recommended for use with all “High” or “Premium” efficiency motors and all motors that have Class F insulation or better. For all non-Class F motors, please contact the factory for proper selection of Acu Drive VF Drive and accessories.
Standard Acu Drive XS VF Drives can be returned within 12 months of invoice only if unused, in original packaging, and subject to a 35% restocking charge. Special drives are non-returnable.
Nema Rated 12 enclosure provides protection against dust, dirt and light splashing. Nema Rated 12 units may be used outdoors when sheltered from direct precipitation and sunlight. Nema Rated 1 enclosure provides basic protection against accidental contact and falling dirt, and is only recommended for ideal, indoor installations.
! CALIFORNIA PROPOSITION 65 WARNING WARNING: Cancer and Reproductive Harm. AVERTISSEMENT: Peut Causer le Cancer et des Dommages au Système Reproducteur. ADVERTENCIA: Cáncer y Daño Reproductivo. www.p65warnings.ca.gov.